Thermal Cameras UK
Compare thermal cameras by professional application, detector resolution, features and manufacturer documentation.
Find the right camera for your application
Thermal imaging devices are not interchangeable. Choose the application first, then confirm native detector resolution, thermal sensitivity, lens field of view and reporting requirements.
- Electrical, HVAC and building inspection cameras — compare handheld measurement, focus and reporting capabilities
- Wildlife and outdoor thermal monoculars — consider lens optics, detection versus identification and operating conditions
- Fixed monitoring and automation systems — check integration, installation and measurement requirements
- Fire and rescue thermal imagers — confirm specialist standards, training and procurement
- Thermal lenses and field of view — check exact mount and camera compatibility
Manufacturer-sourced camera comparison
Manufacturer-published examples, not independent tests, rankings, stock or merchant offers. Check exact UK variants.
| Specification | HIKMICRO B20 | Fluke TiS20+ | FLIR C5 | FLIR E8-XT | Fluke TiS60+ | FLIR K65 | Pulsar Axion 2 XQ35 Pro | HIKMICRO M30 | HIKMICRO Falcon FQ50 (original) | Dräger UCF FireVista | Optris PI 640i | FLIR A700 Advanced Image Streaming | Bullard QXT (original X-Factor) | Guide IR510 Nano N2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Native infrared pixels | 256 × 192 | 120 × 90 | 160 × 120 | 320 × 240 | 320 × 240 | 320 × 240 | 384 × 288 | 384 × 288 | 640 × 512 | 320 × 240 | 640 × 480 | 640 × 480 | 240 × 180 or 320 × 240 (original model configurations) | 400 × 300 (17 µm detector pitch) |
| NETD | <40 mK | 60 mK | <70 mK | <50 mK | ≤45 mK | <30 mK at 30°C | <25 mK (sensor NETD) | <35 mK | <20 mK | 50 mK | 40 mK with selected lenses; 60 mK with 15°/120° optics | Lens dependent; check selected optic | Confirm original unit and detector option | Not stated in available manufacturer manual |
| Image frequency | 25 Hz | 9 Hz or 30 Hz variant | 8.7 Hz | 9 Hz | <9 Hz or 30 Hz variant | 60 Hz | 50 Hz | 25 Hz (UK listing; check regional variant) | 50 Hz | 30 Hz | 32 Hz full frame; 125 Hz at 640 × 120 | 30 Hz | Confirm exact original variant | 50 Hz |
| Field of view | 37.2° × 50.0° | 50° × 38° | 54° × 42° | 45° × 34° | 34.1° × 25.6° | 51° × 38° | 10.7° × 8° | 37.5° × 28.5° | 8.75° × 7° | 50° × 37° | Lens dependent: 15° × 11° to 120° × 100° | Lens dependent | Confirm the fitted original camera configuration | 14.6° × 11.1° (25 mm lens) |
| Minimum focus distance | 0.3 m minimum | 0.5 m minimum | 0.1 m minimum (thermal) | 0.5 m minimum | 0.46 m minimum (fixed focus) | Fixed; depth of field 0.84 m to infinity | 5 m minimum | 0.2 m minimum; manual focus | 5 m minimum | Fixed focus; manufacturer does not specify minimum in summary | Lens dependent; approximately 0.2–0.5 m | Lens dependent | Fixed-focus firefighting imager; check unit specification | Manual focus; 25 mm focal length |
| Object temperature range | −20°C to 550°C | −20°C to 150°C | −20°C to 400°C | −20°C to 550°C | −20°C to 400°C (not calibrated below −10°C) | −20°C to 150°C; 0°C to 650°C (range modes) | Not an object-temperature measuring imager | −20°C to 550°C | Not an object-temperature measuring imager | −20°C to 650°C displayed temperature range | −20°C to 900°C standard; optional range up to 1500°C | Configuration dependent; confirm precise calibrated range | Fire-service operating and measurement specifications require model-specific verification | Observation monocular, not calibrated object temperature measurement |
| Typical application | Building, HVAC and general inspection | Electrical, HVAC and facilities maintenance | Pocket-sized building and electrical inspection | Legacy handheld electrical, mechanical and building inspections | Electrical and facilities maintenance, fixed-focus inspections | Legacy specialist fire-and-rescue thermal imaging; operational procurement and training required | Discontinued outdoor thermal observation monocular; not a radiometric inspection camera | Handheld radiometric inspection for electrical, building, HVAC and automotive use | Outdoor thermal observation with 50 mm F0.9 lens; distinct from inspection cameras | Firefighting and rescue thermal imaging; specialist training and operational procurement apply | Fixed industrial thermography, research and process monitoring; USB/optional integration | Fixed industrial automation and radiometric streaming using RTSP/GVSP protocols | Legacy firefighter thermal imaging camera; not the QXT Pro with X-Factor 2.0 | Legacy outdoor wildlife and site observation; N2 versus N2 Wi-Fi variants differ |
- HIKMICRO B20 model guide · Manufacturer specification
- Fluke TiS20+ model guide · Manufacturer specification
- FLIR C5 — model guide pending · Manufacturer specification
- FLIR E8-XT model guide · Manufacturer specification
- Fluke TiS60+ model guide · Manufacturer specification
- FLIR K65 model guide · Manufacturer specification
- Pulsar Axion 2 XQ35 Pro model guide · Manufacturer specification
- HIKMICRO M30 model guide · Manufacturer specification
- HIKMICRO Falcon FQ50 (original) model guide · Manufacturer specification
- Dräger UCF FireVista model guide · Manufacturer specification
- Optris PI 640i model guide · Manufacturer specification
- FLIR A700 Advanced Image Streaming model guide · Manufacturer specification
- Bullard QXT (original X-Factor) model guide · Manufacturer specification
- Guide IR510 Nano N2 model guide · Manufacturer specification
How thermal imaging works and what to check
Native thermal detector pixels describe spatial detail, while NETD describes how small a temperature difference the camera may resolve under specified conditions. Display resolution and software enhancement are not native detector resolution.
Before purchase, also check emissivity settings, measurement accuracy, operating temperature, minimum focus distance, field of view, reporting tools and the exact UK model variant.
Read our 2026 thermal camera buying guide or explore all model guides.
Thermal imaging buying checklist
Choose the application first, then confirm detector resolution, NETD, focus, field of view, reporting capabilities and the correct UK variant.
These are research-led comparisons based on manufacturer information, not claims of physical testing, live prices, customer review ratings or confirmed stock. Amazon name-search links may earn us a commission; confirm the exact item at the retailer.
Explore model guides
- Bullard QXT X-Factor
- Dräger UCF FireVista
- FLIR A700 Advanced Streaming
- FLIR E-Series 45° Wide Lens
- FLIR E8-XT Thermal Camera
- FLIR K65 Firefighting Camera
- FLIR T-Series 24° Lens
- Fluke 2x Telephoto Lens
- Fluke TiS20+ Thermal Imager
- Fluke TiS60+ Thermal Imager
- Guide IR510 Nano N2
- Hikmicro B20 Thermal Camera
- Hikmicro Falcon FQ50
- Hikmicro M30 Online Thermal
- Optris PI 640i
- Pulsar Axion 2 XQ35 Pro